Studio E/F at the Atrium 4 | MOC Veranstaltungscenter München

Details Studio E/F Atrium 4 on 2nd floor

Rooms / areas Space in m² Theatre Classroom Banquet
Studio E/F in Atrium 4 440 200 100

Our studios are directly connected to the atrium and feature glass facades. Enhance your event with a lounge or throw a party in your own club. Your guests will enjoy a full view of events from this preferred location.

Panoramic view Studio E/F at the Atrium 4

Studio E/F im Atrium 4

Open the panoramic view of studio E/F in a new window.

Technical Data

   
Size 440 m² gross floor space
Floors
  • Raw floor: cement screed on noise impact/thermal insulation layers
  • Flooring covering: wall-to-wall carpeting, wheelchair compatible, flame retardant
  • Hallways: wall-to-wall carpeting
Room height approx. 2.25 to 4.00 m depending on ceiling (s. room details)
Ceiling
  • Suspended acoustic ceilings
  • Integrated ventilation
  • Ceiling suspensions are not possible and not permitted
Walls Plasterboard on stud frame (walls between showrooms and hallway walls)
Windows equipped with sun shades
Doors
  • Partly steel and glass doors: approx. 1.10 m x 2.10 m
  • Partly doors with glazed portions: approx. 2.00 m x 2.10 m
  • Partly wooden doors with glass panes: approx. 0.96 m x 2.10 m
Load capacity
  • Floor load max. 500 kg/m²
  • Trolleys must be fitted with plastic or rubber wheels to avoid damage
  • Metal wheels or casters are not permitted
Communication
  • Telephone (optional)
  • IP connection (optional)
  • W-LAN for organizers (optional)
  • Broadband cable connection (optional)
Electrical installations
  • Multiple 3-KW outlets in the walls
  • Two separate circuits, max. 6 KW
  • Higher output possible on request
Indoor climate
  • Heating and cooling from separate appliances
  • Cooling: 10 °C under outside temperature
Lighting
  • Ceiling and spotlights
  • 300 Lux
Public address / sound system
  • For announcements
  • Can be isolated to specific areas
Sanitary Facilities One WC area each per section, with separate facilities for handicapped
Water connection conditional, subject to request
Access and loading
  • The freight elevator and self-operated lifts can be used in the delivery zones on the ground floors and on the 2nd basement floor for the delivery of heavy and bulky goods
  • The passage to the atrium is 2.10 m wide and 2.00 m tall
  • The freight elevator must be operated by load-lift driver, subject to booking for set-up and dismantling times
Dimensions of load lift
  • Height: 2.60 m
  • Inside cabin width: 3.00 m
  • Door width: 2.50 m
  • Cabin depth: 5.37 m
  • Capacity: 8,000 kg
Self-operated lift dimensions
  • Height: 2.50 m
  • Inside cabin width: 2.00 m
  • Door width: 1.10 m
  • Cabin depth: 2.50 m
  • Capacity: 2,400 kg
Fire Protection The emergency exit door facing the aisle leads directly to an escape / rescue route and must be kept clear of fittings and stored goods at all times. The door must be unlocked when persons are present in the room.